Tab Title 1

Your text...

Tab Title 2

Your text...

Tab Title 1

Your text...

Tab Title 2

Your text...

Tab Title 1

Your text...

Tab Title 2

Your text...

FIRE DETECTION

 

FLAME DETECTOR

        We provides unsurpassed detection of fires from light to heavy hydrocarbon fuels combined with the highest degree

of false alarm rejection. The detector has Division and Zone explosion-proof.

  • Long detection range to carbonaceous fires.
  • Automatic, manual or magnetic optical integrity (oi) testing.
  • Fire, fault and auxiliary relays standard.
  • 0 to 20 mA isolated output (optional).
  • Eagle Quantum Premier LON/SLC output (optional).
  • Tricolor LED indicates normal operation, fire and fault conditions.
  • RFI and EMC Directive compliant.  

 

 

 

The xWatch Explosion-Proof Camera is available as a factory installed option with any of the Det-Tronics X-Series line of flame detectors.

The xWatch Surveiilance Camera produces a high resolulation color video picture using a camera module that is mounted inside an

explosion-proof NEMA 4X rated housing. 

  • Views the exact 90 degree cone of version of the flame detector
  • Available  as  a  stand-alone camera or factory  integrated  to  any     X-Series Flame detector 
  • Detection and viewing of hydrogen and methanol fire locations
  • Provides easy twisted wire pair connection to video switcher for

   The Det-Tronics U5006 Air Duct Smoke Detector is designed to detect the presence of smoke for the primary purpose of controlling blowers and damper in air conditioning and ventilation systems and is intended for use in classified areas in hazardous industrial and commercial locations.

 

    The Detronics U5005 Smoke Setector is a sensitive yet rugged, state0of0the art protection device that is designed for classified areas hazardous industrial and commercial locations.

GAS DETECTION

 

GAS DETECTION

  We provides gas detector capable of detecting hydrocarbon and toxic gases. Which are have many of technologies gas detection such as infrared, electrochemical cell, combustion and latest ultrasonic type. The detector has Division and Zone explosion-proof ratings and is suitable for use in indoor and outdoor applications.

  • Infrared Type
  • 3 or 4 wire, Output 0-20 mA
  • 18-32 VDC required
  • Range 0-100% LEL
  • HART communication
  • Approval SIL/FM/CSA/ATEX/IECEx 

 

  • Infrared Type and
  • Long range detected 5-120 m.
  • 3 or 4 wire, Output 0-20 mA.
  • 18-32 VDC required
  • Rang 0-5 LEL*M
  • HART communication
  • Approval SIL/FM/CSA/ATEX/IECEx
  • Combustiblues       Cataylic
  • Hydrogen Sulfide:  Electrochemical
  • Oxygen                  Electrochemical
  • Carbon Monoxide:  Electrochemical
  • Chlorine:               Electrochemical
  • Sulful Dioxide:       Electrochemical

 

SOLUTION GAS SAMPLING SYSTEM

    We can provide sampling gas detection system which can not install ation gas detector this area or resolve problem hot area application such as cooling tower gas turbine. So this system will have suction gas detection into gas detector.

FIRE & GAS SYSTEM

Fire and Gas System

  The Eagle Quantum Premier (EQP) system combines " fire detection and extinguishing agent release" and "hazardous gas mornitoring" in one complete package. The system is intended for use in hazardous locations and is designed to meet the requirements of approval agencies from around the world.

 

  • The EQP controller is a "Multi-Channel Programmable Controller"
  • RS485 Modbus and Redundant media Control Net interfaces.
  • FM certified as a combination Fire, Gas detection and releasing system.
  • Base system supports up to 60 devices, scalabe up to 246
  • Base system LON length 2000 meters.
  • Total distance to 10,000 meters using network extenders.
  • 8 CH onboard dry contact inputs and 8 CH onboard relay outputs.

 


 EQ3700 DCIO

  • Eight channel Direct Current Input/Output module.
  • Eight flexible 24 VDC I/O channel
  • Each channel can be software configured as an input or an output
  • Each channel can be software configed for supervision of:

          - No supervision

          - Open Circuits

          - Open and Short Circuits

 

 


 EQ3730 EDIO

  • The EDIO provides eight channels of configurable input or output point.
  • Configure each as Supervised or Unsupervised.
  • Inputs can accept fire detection devices:

          - Heat detectors

          - Smoke detectors (2-wire)

          - Unitized flame detectors

  • Eight flexible 24 VDC I/O channels.
  • Each channel can be software configured as an Input or an Output. 

 

 

 


 EQ3710 AIM

  • Eight channel Analog input module.
  • Dual channel mode.
  • Inhibit feature.
  • Supports HART compatible devices (HART Interface Module)
  • Supports 4-20 mA devices only.
  • Compatible 2 and 3 wire 4-20 mA. 

 

 

 

 


 EQ3720 RM

  • Eight channel relay output module.
  • Each 2A, 30 VDC type C relays.
  • Each channel is software configured.
  • DIN rail or panel mount.
  • Configured as normally energized or normally de-energized. 

 

 

 


 EQ3730 Addressable Smoke and Heat Module

  • The ASH is located direcly on the LON of EQP system, with loop of up to 64 addressable devices tied into the ASH.
  • Compatible addressable fire alarm Apollo only.
  • Provides power and communications to 64 addressable devices.
  • Provides remote I/O capabilities via LON/SLC. 

 

 

 


  • Supports Eagle Quantum "Legacy" field devices.
  • EQ2500ARM Agent Release Module.
  • EQ2500SAM Signal Audible Module. 
  • EQ2200IDC Initiating Device Circuit Module.
  • EQ2200IDCGF Ground Fault Monitor.
  • EQ2200DCU & EQ2200DCUEX Digital Communication Units.
  • EQ2400 Network Extender.
  • EQ2100 Power Supply Monitor.

 

 

 

 


The addressable all flame detector is located directectly on the the LON of the EQP system

  • UV (X2200)
  • IR (X9800)
  • UV/IR (X5200)
  • MIR (X3301)

 

 

 


The addressable GASS detector is located directly on the LON of the EQP system as model.

  • PIRECL
  • OPECL
  • UD10

 

 

APPLICATION

 

OEM

We are committed to developing and continuous.

Work engineering system. To meet the needs of   

Its customers to get the most satisfaction Our Scope Capability 

  • Design
  • Engineering
  • Installation Test
  • Commissioning 
  • Training
  • Service
Last month 5554

 